SolarEdge Modbus is a built-in integration that reads and controls SolarEdge inverters locally over Modbus. It connects either through Modbus TCP by host and port, or through a serial RS485 bus with a baud rate and serial port, plus the inverter's device ID. It adds sensors for status, phase currents, DC power, voltage and current, and energy values such as exported and available energy, along with a binary sensor for grid connection. Number and select entities cover controls like active power limit, backup reserve, site export limit, and storage charge, discharge and command modes. Switches handle external production and negative site limit. Home Assistant can discover the inverter on the network, and connection settings can be changed later without removing it.
Automatic summary of Home Assistant's source code. Something wrong? Get in touch
Supports
Works locally Talks to your devices on your own network. No vendor cloud in between.
Set up in the UI Add it in Settings, Devices and services. Nothing to download.
Found by itself Home Assistant spots it on the network and offers to add it.
Adds new devices New devices show up without setting it up again.
Cleans up devices Devices that are gone are removed by themselves.
Change settings later Its connection settings can change without removing it.
Platinum quality Home Assistant's own rating of its code and setup experience.
Updated with Home Assistant Ships and updates with every Home Assistant release.
Provides
- Switches
- Sensors
Setting it up
Home Assistant usually finds it on the network and offers to add it. It can also be added by hand under Settings, Devices and services.
Serial
- Baud rateThe baud rate of the RS485 bus, as configured on the inverter. The SolarEdge default is 115200.
- Serial portThe serial port the inverter's RS485 bus is wired to.
- Device IDThe Modbus device ID of the inverter, as configured on the inverter itself. The SolarEdge default is 1.
Tcp
- HostThe hostname or IP address of your SolarEdge inverter. Modbus TCP has to be enabled on the inverter first, in the installer settings.
- PortThe TCP port the inverter listens on for Modbus requests. The SolarEdge default is 1502.
- Device IDThe Modbus device ID of the inverter, as configured on the inverter itself. The SolarEdge default is 1.
Change the connection
- Baud rateThe baud rate of the RS485 bus, as configured on the inverter. The SolarEdge default is 115200.
- Serial portThe serial port the inverter's RS485 bus is wired to.
- HostThe hostname or IP address of your SolarEdge inverter. Modbus TCP has to be enabled on the inverter first, in the installer settings.
- PortThe TCP port the inverter listens on for Modbus requests. The SolarEdge default is 1502.
- Device IDThe Modbus device ID of the inverter, as configured on the inverter itself. The SolarEdge default is 1.
Texts from Home Assistant's source code, Apache License 2.0.
Entities
- Binary sensorsOn grid
- NumbersActive power limit, Backup reserve, Storage charge limit, Power factor setpoint, Storage discharge limit, External production maximum, Site export limit
- SelectsExport limit type, Export limitation, Storage AC charge policy, Storage command mode, Storage control mode, Storage default mode
- SensorsStatus, Current phase A, Current phase B, Current phase C, DC current, DC power, DC voltage, Available energy, Energy exported, Energy exported phase A, Energy exported phase B, Energy exported phase C, and 23 more
- SwitchesExternal production, Negative site limit
Troubleshooting
- DiagnosticsDownloads a diagnostics file to attach to a bug report.
Shows in Vulpo
Quick Toggle card, Select card, Chart card, Apple Watch, Control Center.Information
More from SolarEdge
SolarEdge Modbus Multi3.2k installs · The Complete Local (Modbus/TCP) SolarEdge Integration for Home …Open
SolarEdge Modbus1.9k installs · Home assistant Component for reading data locally from Solaredg…Open