Screenshots from D4nte85.
What it does
Keeps grid power near zero by adjusting the output of a Solakon ONE inverter with a PI controller and battery charge zones. You pick the grid sensor, inverter entities, helper entities and gains. Optional parts cover surplus export, AC charging, tariff arbitrage and night shutdown.
Written by vulpo.app from the blueprint file by D4nte85. Something wrong, or are you the author? Get in touch
Set it up from your iPhone Vulpo's automation editor turns this blueprint's 13 sections into a form, and shows each run as it happens.
Works with
- Input boolean
input_boolean - Input number
input_number - Logbook
logbook - Number
number - Script
script - Select
select - Sensor
sensor - System log
system_log
What you'll pick when you import it.
๐ GRID SENSOR (External - e.g. Shelly 3EM):
- ๐ Shelly/Grid Power Sensor (REQUIRED)
โก SOLAKON ONE - ENTITIES:
- โก Solakon ONE - Actual Output PowerOptional
- โ๏ธ Solakon ONE - Solar Power (PV Generation)Optional
- ๐ Solakon ONE - Battery State of Charge (SOC)Optional
- โฑ๏ธ Solakon ONE - Remote Timeout CountdownOptional
- โ๏ธ Solakon ONE - Output Power ControllerOptional
- ๐ Solakon ONE - Max. Discharge CurrentOptional
- โฒ๏ธ Solakon ONE - Mode Reset TimerOptional
- ๐ Solakon ONE - Operating Mode SelectionOptional
๐ ๏ธ HOME ASSISTANT HELPER (REQUIRED!):
- ๐ ๏ธ Discharge Cycle State Storage (input_boolean - REQUIRED!)Optional
- ๐ ๏ธ Integral Storage (input_number - REQUIRED!)Optional
- ๐ PI Controller Script (REQUIRED!)Optional
๐๏ธ CONTROL PARAMETERS (PI):
- ๐๏ธ Discharge PIOptional
- ๐๏ธ P Factor (Proportional Gain)Optional
- ๐๏ธ I Factor (Integral Gain)Optional
- ๐ Tolerance Range (Deadband)Optional
- โฑ๏ธ Wait Time After Setting OutputOptional
- ๐ง Adaptive Wait TimeOptional
๐ SOC ZONE PARAMETERS:
- ๐ SOC Threshold "Zone 1 Start" Static (Fallback)Optional
- ๐ Dynamic SOC Threshold "Zone 1 Start" (Optional Override)Optional
- ๐ SOC Threshold "Zone 3 Stop"Optional
- ๐ Max. Discharge Current in Zone 1 (Ampere)Optional
โ๏ธ ZONE 1/2 - PARAMETERS/OFFSETS:
- โ๏ธ Zone 1 - Static Zero-Point Offset (Fallback)Optional
- โ๏ธ Zone 1 - Dynamic Zero-Point Offset (Optional)Optional
- โ๏ธ Zone 2 - Static Zero-Point Offset (Fallback)Optional
- โ๏ธ Zone 2 - Dynamic Zero-Point Offset (Optional)Optional
- โ๏ธ Zone 2 - PV Charge ReserveOptional
๐ SAFETY PARAMETERS:
- ๐ Maximum Output Power (Hard Limit)Optional
๐ MULTI-INSTANCING (Optional):
- ๐ Max. Output Power โ Dynamic (Multi-Instancing)Optional
- โ๏ธ Error Share Helper (input_number, Optional โ Multi-Instancing)Optional
- โ๏ธ AC Charge Error Share Helper (input_number, Optional โ Multi-Instancing)Optional
- ๐ ฮฃ Output Discharging โ Dynamic (Multi-Instancing)Optional
- ๐ Operating Mode of Sibling Instances (Multi-Instancing)Optional
โ๏ธ SURPLUS EXPORT (Optional - Zone 0):
- โ๏ธ Enable Surplus ExportOptional
- ๐ SOC Threshold for Surplus ExportOptional
- ๐ Surplus Export Hysteresis (SOC)Optional
- โ๏ธ PV Surplus HysteresisOptional
- โ๏ธ Surplus State Storage (input_boolean - Zone 0 only)Optional
- โ๏ธ Surplus PV=0 Entry Latch (input_boolean - Zone 0 only)Optional
- ๐ค๏ธ Enable Surplus Forecast Entry (Optional)Optional
- ๐ค๏ธ Surplus Forecast Sensor (Optional)Optional
- ๐ค๏ธ Surplus Forecast Threshold (W)Optional
- โ Enable Surplus Exit Lock (Optional)Optional
- โ Surplus Exit Lock Forecast Sensor (Optional)Optional
- โ Surplus Exit Lock FactorOptional
โก AC CHARGING (Optional):
- โก Enable AC ChargingOptional
- ๐ SOC Charge Target (%)Optional
- ๐ Max. Charge Power (W)Optional
- ๐ Hysteresis AC Charging (W)Optional
- โก AC Charging - Static Zero-Point Offset (Fallback)Optional
- โก AC Charging - Dynamic Zero-Point Offset (Optional)Optional
- โก AC Charge State Storage (input_boolean - AC Charging only)Optional
- ๐ฝ Minimum Charge Power (W)Optional
๐น TARIFF ARBITRAGE (Optional):
- ๐น Enable Tariff ArbitrageOptional
- ๐ฐ Electricity Price SensorOptional
- ๐ Cheap Threshold Static (Fallback)Optional
- ๐ Dynamic Cheap Threshold (Optional Override)Optional
- ๐ด Expensive Threshold Static (Fallback)Optional
- ๐ด Dynamic Expensive Threshold (Optional Override)Optional
- ๐ Tariff Charging SOC Target (%)Optional
- ๐ Tariff Charging SOC Hysteresis (%)Optional
- โก Tariff Charge Power (W)Optional
- ๐น Tariff Charge State Storage (input_boolean - Tariff Arbitrage only)Optional
๐ค๏ธ PV FORECAST TARIFF SUPPRESSION (Optional):
- ๐ค๏ธ Enable PV Forecast Tariff SuppressionOptional
- ๐ค๏ธ PV Forecast Sensor (Optional)Optional
- ๐ค๏ธ PV Forecast Threshold (kWh)Optional
๐ NIGHT SHUTDOWN (Optional):
- ๐ Enable Night ShutdownOptional
Information
- Forum views
- 4.7k
- Likes
- 5
- Checked
- Imports cleanly
- Category
- Energy
- Discussion
- 17 replies on the forum