title: "Smart Heating Control"
description: "Smart Heating Control is a Marketplace integration for Home Assistant. It has 87 installs sharing analytics, works locally and was last updated November 20, 2026."
canonical: "https://vulpo.app/integrations/marketplace/sandreialexandru-smart-heating-control"
url: "https://vulpo.app/integrations/marketplace/sandreialexandru-smart-heating-control.md"
last-updated: "2026-11-20"
version: "1.4"
---

# Smart Heating Control

> Smart Heating Control is a Marketplace integration for Home Assistant. It has 87 installs sharing analytics, works locally and was last updated November 20, 2026.

Smart Heating Control is an integration that manages heating for a house and its rooms based on who is home. It tracks each person as home, nearby or far, and lowers the heating when everyone is away. Each room learns how quickly it warms and cools, so heating starts or stops early enough to reach the target on time. It also handles schedules, open windows, manual changes, vacation periods, outdoor weather and a second heat source. Every room has a Decision sensor that states which rule applied, and alerts cover open windows, unavailable devices and low batteries. It works with a Generic Thermostat, TRVs, other thermostats or a relay, runs locally and is set up in the UI.

Automatic summary of the README and code of sandreialexandru/Smart-Heating-Control. Something wrong, or are you the maintainer and want your own text here? [Get in touch](https://vulpo.app/support)

[Open in My Home Assistant](https://my.home-assistant.io/redirect/marketplace_repository/?owner=sandreialexandru&repository=Smart-Heating-Control&category=integration)

On Home Assistant 2026.10 or older? [Open it in HACS](https://my.home-assistant.io/redirect/hacs_repository/?owner=sandreialexandru&repository=Smart-Heating-Control&category=integration)

## Supports

- **Works locally**: Talks to your devices on your own network. No vendor cloud in between.
- **From the Marketplace**: Installed through the Marketplace, formerly HACS.
- **Actively maintained**: Its author released or pushed a change in the last six months.

## Setting it up

Install it from the Marketplace and restart Home Assistant, then add it under Settings, Devices and services.

### Smart Heating Control

- **Temperature unit**: Every temperature of this house is entered and shown in this unit. It can be changed later with Reconfigure; the values are converted.
- **Name**: Shown on the devices and in the card.
- **People**: People whose location decides home / nearby / far. Leave empty only if presence should not matter: the house state is then always 'home' and only the schedule decides.
- **Nearby zones**: Zones where the house state is 'nearby' (eco), e.g. your city. Outside home and every zone = 'far' (away). Leave empty if you only want home / far.
- **The house state is Home when**: 'At least one' suits most homes. 'Everybody' lowers the heating as soon as one person leaves.

### Heating of the whole house

- **Heated by**: What heats the whole house: a Generic Thermostat, another thermostat (Nest, Tado, Hive…) or a relay that starts the boiler. 'Each room heats separately' when no single device heats the whole home: TRVs or valves on the radiators, electric heaters, air conditioners, underfloor zones; every room is then added with its own device, and with TRVs the boiler relay (or the thermostat that starts the boiler) is picked as the heat source.

### Devices

- **Thermostats**: The thermostat that controls the boiler, e.g. the Generic Thermostat entity (climate.climate).
- **Switches (relays)**: Only when a relay heats the house directly, without a thermostat.
- **Command**: Only for thermostats other than Generic Thermostat. See the room settings for the difference.
- **Heat by the room sensors**: While the house asks for heat (by its temperature sensors, with the hysteresis), the thermostat or the TRVs get the Temperature while heating (by default the maximum temperature of the house), so they keep heating until the house is warm; the rest of the time they get the target. Useful when the device measures in the wrong place (a thermostat in the hallway, a TRV next to the radiator). Needs a temperature sensor. Only with the Temperature command. Not the same as 'Start and stop the source by its temperature': that one is for a thermostat that only starts the boiler for rooms with their own TRVs (then choose 'Each room heats separately' and pick the thermostat as the heat source).

### On / off control

- **Temperature sensors**: Sensors in the room, used instead of the thermostat sensor (more accurate when the thermostat sits next to a heat source). Leave empty to use the thermostat sensor; needed for relays, which have no sensor.
- **Hysteresis**: Heating starts below target minus this value and stops above target plus this value.
- **Minimum on time**: Minimum time on. 0 for heaters that do not mind short cycles.
- **Minimum off time**: Minimum time off between two starts.
- **Use the learned inertia**: Once the room learned how slowly its heating reacts, the heating stops a little early when the heat already given would take the room to the top of the hysteresis band, and starts a little early when the room would fall to its bottom before the heat arrives. The band itself stays the limit. Most useful for slow heating (cast iron radiators, floor heating). Off: only the hysteresis decides.

### Thermostat

- **Hysteresis**: This thermostat does not report when it heats (no hvac\_action): it counts as heating from this far below its set temperature until this far above it, like a relay. Used for the heat demand, the boiler, the heating time, the learning and as the comfort of the optimal stop.

### Heating by the room sensors

- **Temperature sensors**: Sensors in the rooms of the house: the heat demand is decided from them, not from the sensor of the thermostat or of the TRVs.
- **Temperature while heating**: Sent to the thermostat (or the TRVs) while the house asks for heat, never below the target and never above the maximum temperature of the house or of the device. Empty = the maximum temperature of the house.
- **Hysteresis**: The house asks for heat below target minus this value and stops above target plus this value, measured by its sensors.
- **Use the learned inertia**: Once the house learned how slowly its heating reacts, the higher temperature ends a little early when the heat already given would take the house to the top of the hysteresis band by itself, and starts a little early when the house would fall to its bottom before the heat arrives. The band stays the limit. Off: only the hysteresis decides.

### Temperature unit

- **Temperature unit**: Every temperature of this house is entered and shown in this unit. It can be changed later with Reconfigure; the values are converted.

### After setup

- **People**: People whose location decides home / nearby / far. Leave empty only if presence should not matter: the house state is then always 'home' and only the schedule decides.
- **The house state is Home when**: 'At least one' suits most homes. 'Everybody' lowers the heating as soon as one person leaves.
- **Nearby zones**: Zones where the house state is 'nearby' (eco), e.g. your city. Outside home and every zone = 'far' (away). Leave empty if you only want home / far.
- **Use coordinates for nearby zones**: Uses the GPS coordinates: someone in a zone that lies inside a nearby zone (e.g. Office in the city) counts as nearby. Turn off if people have no GPS location.
- **Departure delay**: How long everybody must be gone before the heating is lowered. Avoids reacting to short trips (shop, walking the dog).
- **Arrival delay**: Usually 0: the heating returns as soon as someone is home. Raise it only if GPS sometimes reports 'home' by mistake.
- **Presence sensors**: Keep the house state 'home' while on (mmWave, motion, a switch for people without a phone). Leave empty if everybody has the companion app.
- **Guest mode turns off after**: Guest mode keeps the house state 'home'; it turns off by itself after this many hours. 0 = only manually.
- **Proximity distance sensor**: Distance sensor of the Proximity integration, for preheating on the way home (recommended, with the direction sensor). With several people, its nearest distance sensor. Leave empty without Proximity.
- **Proximity direction sensor**: Direction sensor of Proximity (with several people, its nearest direction of travel). Only the direction tells that someone is coming home: it also applies to the travel time.
- **Travel time sensors**: Travel time to home (Waze, Google Travel Time), one sensor per person: the shortest trip counts (not the one of a person who is home, about 0 minutes). It only tells how close someone is, not whether they are coming home: someone staying nearby keeps the house warm. Proximity is recommended instead, because it can tell the direction.
- **Workday sensor**: Workday integration sensor, so holidays use the profile of weekend days. Without it Mon–Fri are workdays.
- **Calendar**: Optional. An event titled with a profile name (e.g. home\_office) or a level name (e.g. away) applies it while the event lasts. Leave empty if you do not plan days in a calendar.
- **Schedule day starts at**: Leave 00:00. Change it only for night shifts, so a night belongs to the previous day.
- **Outdoor temperature sensor**: Outdoor temperature for the cutoff, season and compensation. If empty, the weather entity temperature is used.
- **Weather entity**: Used for the forecast, for the solar gain and as outdoor temperature when there is no sensor.
- **Turn heating off when it is warm outside**: Stops heating when the outdoor average reaches the cutoff temperature. Needs an outdoor sensor or a weather entity.
- **Use the forecast**: Uses the mean forecast of the next Forecast hours, never a single hour. Heating off by the outdoor average: it may run again when that mean is at or below cutoff minus hysteresis. Heating running: it is turned off earlier when that mean reaches the cutoff, and stays off until the mean falls to cutoff minus hysteresis. Needs a weather entity with an hourly forecast and the cutoff turned on.
- **Heating season**: 'Always' if you switch the season with the Summer mode. 'Between dates' or 'Automatic' to stop heating outside the season by itself. 'Automatic' needs an outdoor sensor or a weather entity.
- **Outdoor compensation**: Raises the target a little when it is very cold outside (walls are colder). Needs an outdoor sensor or a weather entity. Leave off if the rooms keep the temperature well.
- **Ignore windows above**: Open windows do not lower the heating when it is this warm outside. Needs an outdoor sensor or a weather entity. Leave empty to always react.
- **Energy price sensor**: Energy price sensor (dynamic tariff). Leave empty with a fixed price.
- **PV surplus sensor**: Power exported to the grid (W). Only useful with electric heating or a heat pump.
- **Heat source**: The boiler (or the relay that starts the heat source) when the rooms cannot start it themselves (TRVs, zone valves). The integration starts it when rooms ask for heat, and the learning and the heating time count only while it runs. Never the relay a Generic Thermostat already uses. With TRVs and a boiler started by a thermostat that is not in Home Assistant, the learning is not reliable: optimal start and stop are not recommended. Empty: no heat source; the next step can still take circuit relays (zone valves wired to the boiler).
- **Secondary heat source**: Optional, only with a heat source above: a second one (e.g. a heat pump next to the boiler) that heats the same rooms and circuits. Only one of them runs: while the secondary one is in use, the first one stays off. You choose which one in the card or with the Heat source select of the house (by hand, by an automation, or Automatic by a criterion, in the next step). If the chosen one is unavailable, the other one heats. Empty (default): one heat source.
- **Manual changes are kept**: One rule for every manual change. 'Fixed duration' keeps it for the hours below. 'Until next reevaluation' ends when the schedule, presence, a window or the mode changes; the periodic check does not end it.
- **Manual change applies to**: 'Only that room' suits most homes. 'Whole house' copies a manual change to every room; use it only when every room has its own valves.
- **Preheat before the end of a vacation**: The schedule returns this many hours before the vacation ends, so the house is warm when you arrive.
- **Automatic vacation after everyone is far for**: Turns on the vacation by itself after everybody has been far this long. 0 = only manually.
- **Frost protection**: Used with an open window or the Off mode. Rooms with Generic Thermostat use its minimum temperature instead.
- **Maximum temperature**: No level, adjustment or manual change from the integration goes above this.
- **Periodic check every**: Safety check that resends the decision if a device lost it. Changes are applied immediately anyway; 5–15 minutes is fine.
- **Important alerts to**: No heating: the heat source or a thermostat unavailable. Sent at once, also in the quiet hours. Choose phones (notify.mobile\_app\_...) or other notify services. For email write the addresses after the service, e.g. notify.me\_gmail\_com: ana@example.com, ion@example.com (Google Mail needs them). Leave empty for notifications in Home Assistant.
- **Warnings to**: Something to look at: an open window, a low battery, a failed sensor, frost protection in a room, a pause left on, a room colder than the others, a setting that does not work. Email: the addresses after the service, as above. Leave empty for notifications in Home Assistant.
- **Information to**: What the house did by itself: the heating season started or ended, a planned vacation started, the house warms up for your return, the automatic vacation started or ended, guest mode ended by itself. Leave empty to not be told.
- **Tell when an alert ends**: A message when a device works again, a window is closed or a battery was replaced (only for alerts sent to the recipients above). On a phone it replaces the alert.
- **Quiet hours from**: From this time only the important alerts are sent; the others wait until the quiet hours end and are sent only if they still apply. Leave both empty for no quiet hours.
- **Quiet hours until**: End of the quiet hours (may be the next morning).
- **Remind when the pause lasts longer than**: A warning when the heating stays paused this long, then once a day (a pause left on means a cold house). 0 = never.
- **Alert when a window is open longer than**: Alert when a window stays open this long while heating is needed.
- **Alert when a device is unavailable longer than**: Alert when a thermostat or sensor is unavailable this long.
- **Alert when a temperature sensor sends nothing for**: Alert when a room temperature sensor stays available but has sent no value (not even the same one) for this long: a flat battery or a lost signal often keeps the last value. A silent sensor of the room is left out until it reports again, like an unavailable one (the other sensors are used, else the thermostat, else eco). 0 = off. Raise it for sensors that report only when the temperature changes, and for a template or group sensor (an average), which writes a value only when one of its sensors changes.
- **Alert when heating has no effect for**: Alert when a room heats this long, clearly below its target, and its temperature rises much less than its learned model expects: a stuck valve, a heat source that does not start, a window open without a sensor. Only once the room has learned its model (a slow floor heating could not be told from a stuck one before). 0 = off.
- **Low battery below**: Alert when the battery of a room device (TRV, sensor) drops below this.
- **Verify commands**: After 2 minutes checks that the device accepted the command, retries once, then alerts. Turn off only if a device reports its state slowly.
- **Alert when a room stays colder than**: Alert when one room stays this much below its target while others are warm (stuck valve, open window). 0 = off; useful only with several rooms.
- **Heated by**: What heats the whole house: a Generic Thermostat, another thermostat (Nest, Tado, Hive…) or a relay that starts the boiler. 'Each room heats separately' when no single device heats the whole home: TRVs or valves on the radiators, electric heaters, air conditioners, underfloor zones; every room is then added with its own device, and with TRVs the boiler relay (or the thermostat that starts the boiler) is picked as the heat source.

Texts from the code of [sandreialexandru/Smart-Heating-Control](https://github.com/sandreialexandru/Smart-Heating-Control).

## Entities

- **Binary sensors**: Heating season, Warm outside, Heat demand, Window open, Manual change
- **Buttons**: Clear manual changes, Reevaluate, Clear vacation, Clear manual change, Reset learning
- **Dates and times**: Vacation start, Vacation end
- **Numbers**: Level Home, Level Sleep, Level Eco, Level Away, Level Comfort, Level Activity, Nearby temperature
- **Selects**: Mode, Scenario, Schedule profile, Heat source
- **Sensors**: Presence, Outdoor average, Heating time, Decision, Target temperature, Room temperature, Next change, Heating rate, Cooling rate
- **Switches**: Pause, Guest mode, Child lock

## Actions

- **Set manual change**: Set a level or a temperature and keep it as a manual change.
  Fields: Room, Entities, Preset, Temperature, Duration
- **Clear manual change**: Return to automatic control (all rooms when none is given).
  Fields: Room, Entities
- **Set vacation**: Set the vacation period; empty values clear it.
  Fields: House, Vacation start, Vacation end
- **Reevaluate**: Evaluate all rooms now.
  Fields: House
- **Set schedule**: Replace the schedule of a room.
  Fields: Room, Entities, Schedule, Profiles, Profile days

## Troubleshooting

- **Diagnostics**: Downloads a diagnostics file to attach to a bug report.

## From the README

> Heating for Home Assistant that knows who is home, learns how every room heats and tells you why it does what it does.
>
> Warm when you get home, cool when nobody is there, never wasting heat on an open window, and no rules to write. It works with what you already have: Generic Thermostat, TRVs, smart thermostats or a plain relay.

From the README of [sandreialexandru/Smart-Heating-Control](https://github.com/sandreialexandru/Smart-Heating-Control#readme), [MIT License](https://spdx.org/licenses/MIT.html). Shortened.

## At a glance

- Kind: Marketplace integration
- Category: [Climate](https://vulpo.app/integrations/category/climate.md), Thermostats and heating
- Number: 87 installs sharing analytics; 79 GitHub stars
- Connection: Works locally
- Upkeep: Updated in the last 6 months
- Needs: Needs the Marketplace (HACS on 2026.10 and older)
- Latest version: v2.6.6, last updated November 20, 2026
- Domain: `advanced_climate`
- Source: <https://github.com/sandreialexandru/Smart-Heating-Control>
- Issues: <https://github.com/sandreialexandru/Smart-Heating-Control/issues>
- Screenshot: https://vulpo.app/integrations-img/f1386fc93c8002c6.webp (from sandreialexandru/Smart-Heating-Control's README)
- Screenshot: https://vulpo.app/integrations-img/3f80922f4a4a0e9a.webp (from sandreialexandru/Smart-Heating-Control's README)
- Screenshot: https://vulpo.app/integrations-img/bbe39397ecef314b.webp (from sandreialexandru/Smart-Heating-Control's README)

In Vulpo: Quick Toggle card, Button card, Select card, Chart card, Apple Watch, Control Center

Independent directory, made by the developer of Vulpo. Not affiliated with Home Assistant or the Open Home Foundation. [About these numbers](https://vulpo.app/integrations/about)

Last updated 2026-11-20. Source: https://vulpo.app/integrations/marketplace/sandreialexandru-smart-heating-control

---

- HTML version of this page: https://vulpo.app/integrations/marketplace/sandreialexandru-smart-heating-control
- Site index for agents: https://vulpo.app/llms.txt
- Everything in one document: https://vulpo.app/llms-full.txt
- All pages: https://vulpo.app/sitemap.xml