title: "Thermostat Proxy"
description: "Thermostat Proxy is a Marketplace integration for Home Assistant. It has 50 installs sharing analytics and was last updated November 22, 2026."
canonical: "https://vulpo.app/integrations/marketplace/jianyu-li-thermostat-proxy"
url: "https://vulpo.app/integrations/marketplace/jianyu-li-thermostat-proxy.md"
last-updated: "2026-11-23"
version: "1.4"
---

# Thermostat Proxy

> Thermostat Proxy is a Marketplace integration for Home Assistant. It has 50 installs sharing analytics and was last updated November 22, 2026.

From the [repository description](https://github.com/jianyu-li/thermostat-proxy):

> Thermostat Proxy mirrors a physical Home Assistant climate device but lets you choose any remote temperature sensor as its “current” reading. Set targets on the proxy, and it offsets the real...

[Open in My Home Assistant](https://my.home-assistant.io/redirect/marketplace_repository/?owner=jianyu-li&repository=thermostat-proxy&category=integration)

On Home Assistant 2026.10 or older? [Open it in HACS](https://my.home-assistant.io/redirect/hacs_repository/?owner=jianyu-li&repository=thermostat-proxy&category=integration)

## Supports

- **From the Marketplace**: Installed through the Marketplace, formerly HACS.
- **Actively maintained**: Its author released or pushed a change in the last six months.

## Setting it up

Install it from the Marketplace and restart Home Assistant, then add it under Settings, Devices and services.

### Thermostat Proxy

- **Name**
- **Physical thermostat**

Also asked when changing the connection.

### Temperature sensors

- **Sensor name**
- **Temperature entity**
- **Humidity entity (optional)**
- **Add another sensor**

### Manage sensors

- **Choose what to do**

### Remove a sensor

- **Sensor name**

### Replace a sensor

- **Sensor to replace**

### Replace a sensor

- **Sensor name**
- **Temperature entity**
- **Humidity entity (optional)**

### Defaults

- **Adjustment cooldown (seconds)**: Minimum wait time between setpoint adjustments sent to the physical thermostat to prevent short-cycling. Set to 0 to disable.
- **Default sensor**: Sensor preset to activate on startup or when the integration reloads. Choose a specific sensor or 'Last active sensor'.
- **Default target humidity (%)**: Initial target relative humidity percentage slider on the proxy entity (30% - 99%).
- **Humidity overcool limit**: Maximum degrees the system may cool below target temperature to dehumidify the room when high humidity is detected. Set to 0 to disable (default 2.0°).
- **Maximum sync offset**: Maximum degrees of offset allowed between the active sensor and physical setpoint. Protects against wild offsets if a sensor is faulty. Set to 0 to disable (default 10.0°).
- **Maximum safe temperature**: Highest allowable target temperature (safety ceiling). Any target above this is clamped. Set to 0 to disable.
- **Minimum dual setpoint deadband**: Minimum degree separation between heat and cool setpoints sent to the physical thermostat in Heat/Cool mode (e.g. 5.0°F for ecobee). Prevents hardware firmware setpoint clamping. Set to 0 for automatic.
- **Minimum safe temperature**: Lowest allowable target temperature (safety floor). Any target below this is clamped. Set to 0 to disable.
- **Temperature overdrive offset**: Extra degree offset applied to force the physical thermostat to run when the remote sensor is not satisfied but the thermostat is idle. Set to 0 to disable (default 1.0°).
- **Physical thermostat preset name**: Preset name for the physical thermostat's internal temperature sensor (defaults to 'Physical Entity').
- **Physical target change behavior**: How the proxy responds when setpoints are changed directly on the physical thermostat hardware (e.g., turning the physical dial).
- **Sensor change threshold**: Minimum temperature change required at the active sensor before updating the physical thermostat. Filters out noise and frequent micro-adjustments. Set to 0 to disable.

### After setup

- **Adjustment cooldown (seconds)**: Minimum wait time between setpoint adjustments sent to the physical thermostat to prevent short-cycling. Set to 0 to disable.
- **Default sensor**: Sensor preset to activate on startup or when the integration reloads. Choose a specific sensor or 'Last active sensor'.
- **Default target humidity (%)**: Initial target relative humidity percentage slider on the proxy entity (30% - 99%).
- **Humidity overcool limit**: Maximum degrees the system may cool below target temperature to dehumidify the room when high humidity is detected. Set to 0 to disable (default 2.0°).
- **Maximum sync offset**: Maximum degrees of offset allowed between the active sensor and physical setpoint. Protects against wild offsets if a sensor is faulty. Set to 0 to disable (default 10.0°).
- **Maximum safe temperature**: Highest allowable target temperature (safety ceiling). Any target above this is clamped. Set to 0 to disable.
- **Minimum dual setpoint deadband**: Minimum degree separation between heat and cool setpoints sent to the physical thermostat in Heat/Cool mode (e.g. 5.0°F for ecobee). Prevents hardware firmware setpoint clamping. Set to 0 for automatic.
- **Minimum safe temperature**: Lowest allowable target temperature (safety floor). Any target below this is clamped. Set to 0 to disable.
- **Temperature overdrive offset**: Extra degree offset applied to force the physical thermostat to run when the remote sensor is not satisfied but the thermostat is idle. Set to 0 to disable (default 1.0°).
- **Physical target change behavior**: How the proxy responds when setpoints are changed directly on the physical thermostat hardware (e.g., turning the physical dial).
- **Sensor change threshold**: Minimum temperature change required at the active sensor before updating the physical thermostat. Filters out noise and frequent micro-adjustments. Set to 0 to disable.

Texts from the code of [jianyu-li/thermostat-proxy](https://github.com/jianyu-li/thermostat-proxy).

## From the README

> A Home Assistant custom integration that lets you expose a virtual climate entity which mirrors a real thermostat but lets you pick any temperature sensor to act as the “current temperature”. When you change the virtual target temperature, the integration calculates the difference between the selected sensor and the requested set point, then offsets the real thermostat so it behaves as if it were reading the chosen sensor.
>
> - Wraps an existing climate entity; copies all of its attributes for dashboards/automations.
> - Supports any number of temperature sensors. Each named sensor becomes a preset\_mode, so changing the preset swaps the active sensor.
> - Falls back to the real thermostat’s current\_temperature whenever the selected sensor is unknown or unavailable.
> - climate.set\_temperature service adjusts the linked thermostat by the delta between the selected sensor reading and your requested temperature.
> - Exposes helper attributes: active sensor, sensor entity id, real current temperature, and the last real target temperature.
> - Remembers the previously selected sensor/target temperature across restarts and surfaces an unavailable\_entities attribute so you can monitor unhealthy dependencies.
> - Always adds a built-in preset for the wrapped thermostat’s own temperature reading (named Physical Entity by default, but you can rename it during setup) so you can revert or set it as the default…

From the README of [jianyu-li/thermostat-proxy](https://github.com/jianyu-li/thermostat-proxy#readme), [MIT License](https://spdx.org/licenses/MIT.html). Shortened.

## At a glance

- Kind: Marketplace integration
- Category: [Climate](https://vulpo.app/integrations/category/climate.md), Thermostats and heating
- Number: 50 installs sharing analytics; 27 GitHub stars
- Connection: Connection not stated
- Upkeep: Updated in the last 6 months
- Needs: Needs the Marketplace (HACS on 2026.10 and older)
- Latest version: 2026.11.0, last updated November 22, 2026
- Domain: `thermostat_proxy`
- Source: <https://github.com/jianyu-li/thermostat-proxy>
- Issues: <https://github.com/jianyu-li/thermostat-proxy/issues>
- Screenshot: https://vulpo.app/integrations-img/fdb67560ca8d668b.webp (from jianyu-li/thermostat-proxy's README)
- Screenshot: https://vulpo.app/integrations-img/64b323b7aad2d72f.webp (from jianyu-li/thermostat-proxy's README)

In Vulpo: Climate card, Apple Watch, Climate Live Activity (Pro)

[Widgets & Live Activities in Vulpo](https://vulpo.app/features/widgets-and-live-activities)

Independent directory, made by the developer of Vulpo. Not affiliated with Home Assistant or the Open Home Foundation. [About these numbers](https://vulpo.app/integrations/about)

Last updated 2026-11-23. Source: https://vulpo.app/integrations/marketplace/jianyu-li-thermostat-proxy

---

- HTML version of this page: https://vulpo.app/integrations/marketplace/jianyu-li-thermostat-proxy
- Site index for agents: https://vulpo.app/llms.txt
- Everything in one document: https://vulpo.app/llms-full.txt
- All pages: https://vulpo.app/sitemap.xml